Phone
High voltage direct current circuit breakers require a high-speed actuator and proper brake system that can absorb the kinetic energy of fast-moving mass to prevent damage and malfunction of the
One of the most causing closing fault of high voltage circuit breaker is closing spring failure. In order to avoid such closing fault, this paper analyzed the relationship between energy of closing spring and its load, as well as the experiment carried out to get the minimum energy when closing. The time-varying static stress relaxation
Abstract: High-voltage circuit breakers (HVCBs) are essential protection devices which should also be included in power system reliability analysis. When using Monte
This paper estimates the recurrent failure process of high-voltage circuit breakers, considering the impact of age, yearly operation frequency, corrective
This paper analyzes the mechanical characteristic of the hydraulic HV circuit breaker in the smart substation, selects the energy storage motor combined with the fuzzy comprehensive evaluation model, opening circuit operation and closed circuit operation as the comprehensive evaluation factors, determines the weight distribution
High voltage circuit breakers (HVCBs) play an important role in the protection and control of power systems. The faults of HVCBs will directly affect the running of the power system. Mechanical faults of HVCBs'' mechanical operation mechanism are the major reasons for HVCBs faults.
According to the above analysis, the failure of the breaker bolt mainly exists in the following two aspects: (1) The failed bolt not only bears static load, but also withstands the pulsating load caused by external pressure and temperature changes. Since the circuit breaker adopts the spring mechanism, the operating work is large, and the
With the increasing and unprecedented scale and complexity of power grids, component failures are becoming the norm instead of exceptions [1,2,3].High voltage circuit breakers (HVCBs) are directly linked to the reliability of the electricity supply, and a failure or a small problem with them may lead to the collapse of a power network through chain reactions.
In this paper, we propose a method for HVCBs mechanical fault diagnosis utilizing variational mode decomposition (VMD) based on improved time segment energy entropy (ITSEE) and a new hybrid classifier. Firstly, the signal is decomposed into $K$ intrinsic mode functions (IMFs) via VMD to establish a component matrix. Secondly, the
Lithium-ion batteries (LIBs) play a major role in energy storage for a wide range of portable electronic devices and electric vehicles [1], [2], [3]. However, the state-of-the-art LIBs are reaching their upper limit of energy density [4], [5], [6], which is not high enough to meet the ever-growing demand for large-scale, high-energy-density batteries.
Hitachi Energy has signed a frame agreement with Norway''s major distribution grid company, BKK Nett to install EconiQ™ Live Tank Breakers (LTA) 145 kV in more than 10 substations in the western region. For Hitachi Energy, this is the very first frame agreement globally for its EconiQ eco-efficient breaker technology.
A model to rectify the point through simulation of the spring drive operating mechanism as the main origin of major failures for a real case, i.e., a 72.5 kV, SF6, EDF high voltage circuit breaker (HVCB). Supervised machine learning (ML) methods have been increasingly applied in the fault detection of components. However, they relied on
The diagnostic process is cumbersome and the accuracy is not high, which fails to maximize CNN''s self-learning ability. To solve these problems, this paper presents a fault diagnosis method of circuit
Mechanical fault diagnosis of high-voltage circuit breakers (HVCBs) based on vibration signal analysis is one of the most significant issues in improving the reliability and reducing the outage
In order to improve the reliability of the high voltage circuit breaker, a status monitoring system for high voltage circuit breaker based on the field programmable gate array is developed. With XC7A35TFGG484-2I as the control core, the system can collect, convert, transmit and display monitoring data, and can monitor the current of the closing and
The experimental results show that the composite feature extraction method is more effective for circuit breaker fault diagnosis. 2. Measuring system and measuring process. Since the spring-operated high-voltage circuit breakers have the same motion principle and are widely used, this paper selects the ZN-63 indoor HVCB as the research
The organization of this thesis can be described as followed: Fundamentals of HV circuit-breakers composed of functions and components of HV circuit-breakers, types of HV circuit-breakers and switching transients are represented in Chapter 2. Chapter 3 represents the switching stresses of HV circuit-breakers. In this chapter, the stresses of
Axial blast circuit breakers are well-suited for Extra High Voltage (EHV) and Ultra High Voltage (UHV) applications. In this type of circuit breaker, a high-pressure air blast is directed longitudinally, aligning with the arc. To mitigate transient over-voltages, resistance switching is implemented.
IGH voltage circuit breakers (HVCBs) have been recognized as the critical components owing to their role in protection and switching. Therefore, any failure in these components could highly influence the reliability and resiliency of power systems. Many
The opening and closing time test of 500kV high voltage circuit breaker can evaluate the mechanical characteristics and three-phase synchronization performance of the circuit breaker.
of High Voltage Circuit Breaker YAKUI LIU 1, GUOGANG ZHANG 1, (Member, IEEE), CHENCHEN ZHAO1, fatigue failure of circuit breaker energy storage spring has drawn a series of attentions [16
The product has a proven lifetime exceeding 30 years and meets M2 mechanical class for 10,000 operations. HPL B is designed and type tested in accordance with international standards IEC and ANSI is also tested to national standards such as GOST, DL, DIN. HPL B is available up to 1100 kV as a circuit breaker and up to 550 kV as a disconnecting
its heating or mechanical interaction, the consequences may be extended to additional areas. The 4100-V or higher control board failures almost always involve the cables, buswork, or circuit breakers that are installed in them, except when some external condition, such as sprinkler activation or mechanical
Mechanical faults of high voltage circuit breakers (HVCBs) are one of the most important factors that affect the reliability of power system operation. Because of the limitation of a lack of samples of
Mechanical faults are the main causes of abnormal opening, refusal operation, or malfunction of high-voltage circuit breakers. Accurately assessing the
In order to implement the accurate and convenient mechanical fault diagnosis of high voltage circuit breakers, this paper proposed a method of using sound signals to recognize HV circuit breaker
In recent years, it is common to report that the high-voltage circuit breaker cannot work normally due to the spring failure: the breaking of the closing spring causes the failure of the high
In this paper, a new kind of coupling mechanical high-voltage direct current (HVDC) circuit breaker topology based on pulse transformer is proposed and its working principle is analysed in detail. On the basis of the requirement of 160 kV rated voltage, and 9 kA breaking current, the varying trend and design principle of parameters
To maintain redundancy, separate battery supplies must be provided for each protection. 4. Separate routing of wiring/. Equipment and wiring are physically separated t o reduce possibilities of common faults. 5. Separate Inputs. The protections utilize signals from completely separate current and voltage transformers.
The force of closing spring under the minimum energy required f or closing of high-voltage circuit. breaker is the minimum force allo wed. When the force of closing spring f=2656.2N (energy of
AC circuit-breakers interrupt short-circuit currents at current zero. arc because at this instant the input power from the system is zero (U x I = 0), At current zero, it is possible to cool efficiently the arc so that its temperature decreases rapidly and the interval between contacts becomes non conductive.
Abstract — This paper proposes the failure rates of power circuit breakers at the system voltage level of 115kV for control and protective system in power substation. Firstly, the
High voltage circuit breaker cannot be closed Case 1: Fault equipment: a 10kV high voltage switch cabinet. Trouble phenomenon: This high-voltage cabinet is used to control a 10kV overhead line. After the line is overhauled, prepare to switch on and send power. When the microcomputer issued a closing command, the circuit breaker had a
To address the problem of mechanical defect identification in a high-voltage circuit breaker (HVCB), this paper studies the circuit breaker vibration signal and proposes a method of feature
Early diagnosis of high-voltage circuit breaker failure is an important way of improving the reliability of power system. In this paper, the application of high-performance support vector machine
1 · Fault diagnosis of circuit breaker energy storage mechanism based on current-vibration entropy weight characteristic and grey wolf optimization–support vector
1. Introduction. High voltage circuit breakers (HVCBs) are the critical control and protective devices of the modern power system [1], [2] the event of abnormal situations such as short circuit in power system, it would cause serious consequences and huge losses in the safety of life and properties if the HVCB have malfunction, refusal or
High-voltage circuit breakers (HVCBs) handle the important tasks of controlling and safeguarding electricity networks. In the case of insufficient data samples,
Mechanical fault diagnosis of high-voltage circuit breakers (HVCBs) based on vibration signal analysis is one of the most significant issues in improving the reliability and reducing the outage cost for power systems. The limitation of training samples and types of machine faults in HVCBs causes the existing mechanical fault diagnostic
© CopyRight 2002-2024, BSNERGY, Inc.All Rights Reserved. sitemap